Faria Instruments Antares IS0250a Manuale Utente

Navigare online o scaricare Manuale Utente per Navigatori Faria Instruments Antares IS0250a. Faria Instruments Antares IS0250a User's Manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 44
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
Owner’s Manual
IS0250a
ecr7106 9/2007
TM
Vedere la pagina 0
1 2 3 4 5 6 ... 43 44

Sommario

Pagina 1 - Owner’s Manual

Owner’s ManualIS0250aecr7106 9/2007TM

Pagina 2

8 Step 2: TANK SETUP Tank Setup will allow you to 1) Name each tank 2) Set each tank’s capacity and 3) Set a low level warning for each tank. Note

Pagina 3

9 Step 3: Depth Setup Depth Setup will allow you to set the shallow water alarm, set the deep water alarm, and set the keel offset. Note: A digi

Pagina 4

10 Part III: Operating Instructions Your Faria Antares unit has 8 main display screens and an optional Radio Control Screen. When a screen is sel

Pagina 5

11 GAUGE SCREEN 1 / GAUGE SCREEN 2 Gauge Screen 1 and Gauge Screen 2 provide a quick glance at up to 12 different gauge functions. Ea

Pagina 6

12 QUICK VIEW SCREEN The Quick View screen provides a large digital display for quick, easy reading. Use the up or down navigation buttons to s

Pagina 7 - BUTTON FUNCTIONS

13 FUEL FLOW MANAGER SCREEN The Fuel Flow Manager screen provides all the necessary information to optimize the fuel consumption perfor

Pagina 8

14 DEPTH / TEMP SCREEN The Depth / Temp screen will display the current depth, air temperature, and water temperature. For Depth and Water Temp

Pagina 9

15 TANK LEVEL SCREEN The tank level screen will display tank level information as reported by the tank’s level sender. Your

Pagina 10

16 GPS SCREEN Magnetic North Signal Available No Magnetic North Signal Available The GPS Screen will display COG, Latitude, and Longit

Pagina 11

17 RADIO CONTROL SCREEN To enter the Radio Control Screen, press the button The Radio Control Screen allows you to control

Pagina 13

18 MAIN MENU SCREEN The Main Menu screen provides access to the various setup screens available on your Faria Antares unit. Use the up or dow

Pagina 14

19 Part IV: Menu Options / User Settings LIGHTING This screen can also be accessed by tapping the button at any time. Use the up o

Pagina 15

20 FUEL MANAGER STOP: Your fuel tanks must be activated and set to the proper capacity before the fuel manager will become functional. Refer to Pa

Pagina 16

21 SYSTEM SETUP Refer to Part II: System Setup, pages 6-9 for detailed information.

Pagina 17

22 UNITS The Units screen will allow you to change the display values for Fluids, Pressure, Depth, Temperature, Speed, and Distance. Use the left

Pagina 18

23 CALIBRATE Your Faria Antares unit is factory calibrated to give you optimal performance with the senders installed on your boat. I

Pagina 19

24 SPEEDOMETER CALIBRATION Step 1: Press to begin speedometer calibration, then follow the on-screen instructions. Your actual speed as reported

Pagina 20

25 TRIM CALIBRATION Press to begin Trim Calibration, then follow the on-screen instructions. Step 1: Set your engine to its full down posi

Pagina 21

26 SELF TEST Your Faria Antares will automatically run a self-diagnostics test when this menu option is selected. The test may t

Pagina 22

27 MASTER RESET This screen will appear when Master Reset is selected from the Main Menu screen. will automatically be highlighte

Pagina 23

2 TABLE OF CONTENTS Part I: Introduction 3 Basic Operation 4 Part II: System Setup 6 Input Setup 6 Tank Setup 8 Depth Setup 9 Part I

Pagina 24

28 DIAGNOSTICS The Diagnostics page displays the most recent engine error codes as reported by the engine’s ECU. “Hours” indicates at what engine h

Pagina 25

29 Part V: Alarms Your Faria Antares unit will display 3 types of alarms; 1) Engine Alarms 2) Fuel/Tank Level Alarms and 3) Depth Alarms. When a

Pagina 27

30 ENGINE ALARMS LIST Your Antares unit will display the engine alarms listed in table 5.1. The Antares will display engine alarms as they are repor

Pagina 28

31 Part VI: Installation / Wiring Diagrams INSTALLATION Your Faria Antares unit can be mounted to your instrument panel in 4 ways; Panel Mount, Flu

Pagina 29

32 Flush Mount Step 1: Cut a square hole with rounded corners to match the dimensions as indicated in the figure below. Step 2: Install mounting stu

Pagina 30

33 Gauge Mount Step 1: Cut a 3 3/8” round hole in your boat’s console Step 2: Insert the Antares through the hole, placing the Gauge mount gasket (G

Pagina 31

34 Gimble Mount Step 1: Locate a flat surface on your boat’s console to install the Antares Gimble Mount Bracket. Step 2: Using a 3/16” drill bit,

Pagina 32

36 GPS FARIA BUS ENGINE ECU RS232 HN0604

Pagina 33

37 HN0605 – Power / Analog Harness FARIA BUS Power / Gnd Tank 1 / Tank 2 Tank 3 or Trim Air Temp or Analog PWS

Pagina 35

38 HN0604 HN0605

Pagina 36

39 Part VII: FAQ / Troubleshooting The following items are common questions regarding the installation and use of the Antares unit. If you are expe

Pagina 38

P.O. Box 983, Uncasville, CT USA 06382-0983 Tel: 860-848-9271 Fax: 860-848-2704 Customer Service: 800-473-2742www.faria-instruments.com*IS0090E 10/

Pagina 40

3 Part I: Introduction Congratulations on the purchase of your Faria Antares unit. This owner’s manual contains very important informati

Pagina 41

4 IMAGE 1.1 To begin, simply press the button to turn on your Antares. It will take about 5-7 seconds for the Antares to complete its start-up p

Pagina 42

5 BUTTON FUNCTIONS (B1): Returns to previous page when in menu / setup / radio control screens, silences alarms (B2): Use to change scree

Pagina 43 - Faria® Marine Instruments

6 Part II: System Setup SYSTEM SETUP Your Faria Antares unit should already have been setup by either the boat manufacturer or by

Pagina 44

7 *For sender connection information, refer to wiring diagram HN0605 in Part VI (pg. 36) for further information. TANK 1 – Select the type of level

Commenti su questo manuale

Nessun commento